Ripple
These charts show the measured levels of ripple on the +12V rail for each PSU at a range of load levels. Lower results are better, and levels that fall outside of Intel's specifications are considered a fail and highlighted in red.
-
Be Quiet! Dark Power Pro 10 850W
-
SilverStone ST1000-PT 1,000W
-
In Win Classic Series C 900W
Millivolts peak-to-peak (blue = pass; red = fail)
-
Be Quiet! Dark Power Pro 10 850W
-
SilverStone ST1000-PT 1,000W
-
In Win Classic Series C 900W
Millivolts peak-to-peak (blue = pass; red = fail)
-
Be Quiet! Dark Power Pro 10 850W
-
SilverStone ST1000-PT 1,000W
-
In Win Classic Series C 900W
Millivolts peak-to-peak (blue = pass; red = fail)
-
Be Quiet! Dark Power Pro 10 850W
-
SilverStone ST1000-PT 1,000W
-
In Win Classic Series C 900W
Millivolts peak-to-peak (blue = pass; red = fail)
Want to comment? Please log in.